30+ years home header_03 WQA
home about products support contact us
spacer
home
about us
products
support
contact
spacer2
agriculture
animal health
Eco-Irrigation
horticulture
landscape
pools
water treatment
markets
spacer3
warranty
testimonials
tradeshows
calculators
catalog
manuals
faqs
spacer4
spacer7
spacer7

 


CP33: How To Use The Injection Control Panel

The Injection Control Panel is used to set the volume of solution to be injected into the water flow.
icp setting

1. Locate the control valve (A), inlet gate valve (B), outlet gate valve (C), and needle valve (D) in the diagram.
2. With your system water flow at its maximum, control valve (A) is fully open.
3. The inlet gate valve (B) and outlet gate valve (C) should be completely closed before proceeding.
4. Connect a water hose from inlet gate valve (B) to the Injection Control Panel:


High Volume Installation


If you need an injection volume in gallons-per-hour, use the bottom left-hand side of the Injection Control Panel.
Gallons Per Hour Injection
Injection rate is adjusted by turning valve “B”.
High Volume

Low Volume Installation

If you need an injection volume in ounces-per-hour, use the bottom right-hand side of the Injection Control Panel.
Ounces Per Hour Injection
Injection rate is adjusted with the needle valve on the Injection Control Panel.
Low Volume

To determine if you need gallons per hour or ounces per hour, use our handy calculators:


5. Cap off the bottom input to the Injection Control Panel that you are not using.
Injection Control Panel
Depending on which side of the Injection Control Panel you use, the other side is capped off (cap included)
ICP

6. Ensure the short blue hose provided with the injector is connected from the outlet of the Injection Control Panel (top right side) to the inlet T on
the injector.
hose connection
7. Ensure a water hose is connected from the outlet T on the injector to
outlet gate valve (C).
8. Open outlet gate valve (C) completely and then open inlet gate valve
(B) until it is also fully open.

9. To set the volume of injection, slowly close control valve (A) until the
top of the float inside the Injection Control Panel is positioned at the
highest injection volume on the Injection Control Panel.
Panel
If you are using high-volume injection (gallons-per-hour), use the inlet gate valve (B) to fine-tune the injection volume to the exact amount desired.
 
If you are using low-volume injection (ounces-per-hour), use the needle valve to fine-tune the injection volume to the exact amount desired. (Over tightening <closing> the needle valve will cause damage to the needle and seat.)
Panel
Note: fluctuations in your system’s water pressure will cause the float to bounce; the injection volume indicated by the top of the float at the highest point of the bounce is the injection volume the CP33 will output.

for "Printer-Friendly" .pdf version of this information , click here


To learn more, contact Chemilizer at 1.800.234.7211


hn55
cp33
c3p
 
show schedule
 
Chemilizer Products, a Hydro Systems Company Brand, 3798 Round Bottom Road, Cincinnati, Ohio 45244 USA
info@chemilizer.com ©2010 Chemilizer Products, Inc. All rights reserved.